If you have trouble displaying this email, view it as a webpage.
   

October 2026

Subscribe

Contact

Follow

 

In this issue

How-to: Prepare bone marrow for processing
Before you can process bone marrow for hematopoietic stem cell transplantation, you need to take these two essential steps. Read more >

Resource spotlight
Boost your knowledge of the Spectra Optia™ Apheresis System protocols with these handy reference materials. Explore now >

Did you know?
Discover what’s different about the tubing set and filler used for bone marrow processing (BMP). Learn more >

Q&A
Do you need to filter harvested bone marrow before processing? Get the answer >

Events
Sign up for workshops on three Spectra Optia protocols and a webinar exploring custom prime. Find details >

The Access Point newsletter is designed to keep Spectra Optia users informed and connected with helpful insights and resources to support patient care. If you have questions, comments, or suggestions for future topics, please let us know.
Spectra Optia protocols

How-to: Prepare bone marrow for processing

BMP is an important part of hematopoietic stem cell transplantation. And Spectra Optia gives you an efficient and effective way to perform it.* But before you begin, learn about these two essential preparation steps.

Learn more >
Resource spotlight
 
 
BMP Procedure Brochure
Download this brochure for more details on BMP, including on-screen guidance and an overview of the Spectra Optia™ BMP Accessory Set.

Protocol Overview
Refer to this handout for a quick look at the different protocols available on Spectra Optia, with information on compatible software, sets, and fillers.
 
Did you know?

One Spectra Optia procedure does not use a matching filler and tubing set.
The BMP procedure on Spectra Optia is the only procedure on the device that does not use the matching filler and tubing set. Instead, it uses a combination of the Spectra Optia™ IDL Set and the standard filler, as well as the BMP Accessory Set.
 
 
Learn more about the BMP procedure in this brochure and order the filler and disposable sets from our 2026 catalog.
Your questions, answered

Dear Access Point,

Do we need to filter our harvested bone marrow before processing it?
— Kurt in Madison, WI
Dear Kurt,

Yes, the bone marrow must be filtered prior to the bone marrow processing procedure. That’s because when bone marrow is collected, it can contain bone particles, fat, or cellular debris. All these particulates must be removed prior to processing.

We recommend following your facility’s policies for filtering the bone marrow. If additional filtration is needed, there is a 200-micron filter on the administration line of the BMP Accessory Set. Please refer to your Spectra Optia operator’s manual for additional information.

If you have a specific question about the Spectra Optia system, let us know. We will feature a reader question in each Access Point edition. Be sure to tell us your first name, hometown, and state or province. Questions not featured will be answered directly via email.
Submit a question
 
Events
Live From Lakewood 

Exploring Custom Prime on the Spectra Optia Apheresis System | November 12, 2026

All Live From Lakewood sessions begin at 12 p.m. MT. Learn more and register to attend any of these live and interactive webinar sessions hosted from our headquarters in Lakewood, Colorado. If you would like to have a specific topic covered in one of these webinars, please send us an email.
 
Successions Workshops

Therapeutic Plasma Exchange (TPE) | January 27 | Aliso Viejo, CA
Hosted by Terumo Blood and Cell Technologies

Continuous Mononuclear Cell Collection (CMNC) | January 28 | Aliso Viejo, CA
Hosted by Terumo Blood and Cell Technologies

If you are interested in attending any of these workshops, please email Successions@TerumoBCT.com, and we will send you an invitation to register.

Need support?
You're on the front lines of care, and we're here to assist.
Contact us online.

Access previous issues
Stay up to date
Follow us on LinkedIn for the latest news, webinars, and other happenings that
could help you make the most of your Spectra Optia system and your relationship with
Terumo Blood and Cell Technologies to do even more for your patients.
Spectra Optia™ is either a registered trademark or trademark of Terumo BCT, Inc. in the United States and/or other countries. See TerumoBCT.com/Trademarks for details.
Sources for “Dear Access Point”: Terumo Blood and Cell Technologies. Spectra Optia Apheresis System Operator’s Manual. Part no. 1000036875. August 2023.
Source for “Did You Know?”: Terumo Blood and Cell Technologies. Spectra Optia Apheresis System Protocol Overview. Part no. TS-OPTI-01131. April 2025.

Intended use
The Spectra Optia Apheresis System, a blood component separator, may be used to perform the following therapeutic apheresis, cell collection, and cell processing procedures:*
◼ Therapeutic plasma exchange
◼ Therapeutic plasma exchange with a secondary plasma device
◼ Red blood cell exchange, depletion, and depletion/exchange
◻ Red blood cell exchange, depletion, and depletion/exchange for the transfusion management of sickle cell disease in adults and children (U.S.)
◼ Mononuclear cell collection from the peripheral blood
◼ Granulocyte collection from the peripheral blood
◼ White blood cell depletion
◻ White blood cell reduction for patients with leukocytosis at risk for leukostasis (U.S.)
◼ Platelet depletion
◼ Processing of harvested bone marrow
◻ Processing of harvested bone marrow for the purpose of facilitating hematopoietic reconstitution (U.S.)

*Products and services are available in selected areas subject to regulatory approval in each country. 
©2026 Terumo BCT, Inc. | All Rights Reserved | TS-OPTI-03207 | TerumoBCT.com

Terumo BCT, Inc. | 10811 West Collins Avenue, Lakewood CO, 80215, USA | 303.231.4357
Unsubscribe | Manage Subscriptions | Privacy |   |     |